100 MHz Analog Oscilloscope
Description
Analog oscilloscope, which adopts cathoderay tubes to display a waveform, is the first oscilloscope that is used by engineers. 100 MHz analog oscilloscope is used to observe the change of an electrical signal over time. The constantly varying signal voltages can be graphed on the screen, which is commonly referred to as a waveform. It is a kind of portable oscilloscope.
Application
1. 100 MHz analog oscilloscope is widely used in science, pharmacy, engineering and telecommunication industries.
2. Portable oscilloscope can be used to observe waveforms of different signal amplitudes over time. It can also be used to test different powers such as voltage, electric current, frequency, phase difference and amplitude modulation.
Parameters of 100 MHz Analog Oscilloscope
CRT | ||
Screen | 6" screen with internal graticule: 8×10 divisions(1 division=1cm) | |
Accelerating Voltage | +12kv | |
Phosphor | P31 standard | |
Focusing | Adjustable | |
Trace Rotation | Adjustable | |
Intensity Control | Provided | |
Vertical Deflection | ||
Bandwidth | DC Coupling | DC to 100MHz |
AD Coupling | 10Hz to 100MHz | |
Deflection Factor | 2mV/div to 5V/div in 11 steps of 1-2-5 sequence | |
Display Mode | CH1, CH2, ADD, ALT, CHOP | |
Accuracy | Normal: ±3%, | |
Input Impedance | 1MΩ, 27pF | |
Max. Input Voltage | 400V (DC+AC peak) | |
CH1 Output | 20mV/div (in 50Ω, 20Hz to 10MHz) | |
Rise Time | ≤3.5ns | |
Polarity Inversion | CH2 Only | |
Horizontal Deflection | ||
Time base A | 0.05μs/div to 0.5s/div in 22 steps of 1-2-5 sequence. | |
Display Mode | A, ALT, B | |
Hold-off Time | Variable up to 2 × sweep time | |
Time base B(delay) | 0.05μs/div to 50ms/div | |
Delay Time | 1μs to 5s | |
Delay Time Jitter | Less than 1/20000 | |
Sweep Magnification | X10 | |
Accuracy | Normal: ±3%, Magnified: ±5% | |
X-Y Mode | ||
X-Axis | CH1, CH2: 2mV/div to 5V/div ±3%, EXT: 0.1V/div ±5% | |
Y-Axis | CH1, CH2: 2mV/div to 5V/div ±3% | |
X-Y Phase Difference | 3° or less (DC-50kHz) | |
Trigger System | ||
Mode | NORM, AUTO, TV-V, TV-H | |
Trigger Source | CH1,CH2,VERT, LINE, EXT | |
Coupling | AC, DC, HF-REJ, LF-REJ | |
Slope | + or - | |
Sensitivity & Frequency | 10Hz-20MHz: 0.5 div (0.05Vp-p EXT), 20MHz-100MHz: 1.5div (0.15Vp-p EXT) 1.0 div or 1Vp-p, TV | |
Cursor Readout | ||
Cursor Measurement | △V,△T, 1/△T | |
Cursor Resolution | 1/100div | |
Cursor Range | Vertical: ±3div, Horizontal: ±4div | |
Calibrator | ||
Frequency | 1kHz ±5% | |
Voltage | 2Vp-p ±2% | |
Other Function | ||
Setting Save & Recall | 10 sets of panel setting | |
Power Supply | ||
Voltage Range | 220V/110V ±10% | |
Fuse | 0.5A/1A | |
Frequency | 50Hz-60Hz | |
Physical | ||
Dimensions | 310 (W) × 150 (H) × 455 (D) mm | |
Weight | 10kg |
Notes
1. 100 MHz analog oscilloscope should be equipped with suitable line voltage.
2. To avoid electrical shock, the protective grounding conductor of power cord should be connected to ground.
Maintenance
1. To maintain good ventilation of 100 MHz analog oscilloscope, regular cleaning should be carried out.
2. Do not spray cleaner directly onto the instrument when cleaning this dual trace oscilloscope and use a soft cloth with mild detergent and water instead.
- 20 MHz Analog OscilloscopeOscilloscopes are used to observe the change of an electrical signal over time. The constantly varying signal voltages can be graphed on the screen, which is commonly referred to as a waveform.1. 20 MHz analog oscilloscope with probe is widely used in science, medicine, engineering and telecommunication industry. 2. It can also be used to...