Home » Products » Function Signal Generator » DDS Function Generator » 10 MHz DDS Function Generator
10 MHz DDS Function Generator

10 MHz DDS Function Generator

Description
10 MHz DDS function generator generates different type of electrical waveforms over a wide range of frequencies. Arbitrary waveform generator can be used for developing, testing and repairing electronic equipment.

Features
1. 10 MHz DDS function generator features high resolution, accuracy and stability.
2. VFD display and rubber keypad of arbitrary waveform generator makes it more convenient to operate the machine.
3. It has friendly user interface which is convenient for the users to set parameters.

Parameters of 10 MHz DDS Function Generator

Model SM-4010
Waveforms
Main Waveforms Sine, Square (Only sine is available above 40MHz)
Waveform Length 8-16000 points
Amplitude Resolution 12 bit
Sampling Rate 200 MSa/S4
Built-in Arbitrary Triangle, +Ramp, +Pulse, Rise/fall exponential, Rise/fall logarithm, Gauss noise, Cardiac, SIN(X)/X, DC.
Waveform Length 8-16000 points
Amplitude Resolution 10 bits
Sampling Rate 10 MSa/S4
Arbitrary Waveforms
Waveform Length 8-16000 points
Amplitude Resolution 10 bit
Sampling Rate 10 MSa/S4
Memory 6*4 k
Waveform Characteristic
Sine Harmonic Distortion -35 dBc
Sine Distortion ≤1% (20Hz-100KHz)
Square Rise/fall Time ≤10ns
Frequency Characteristic
Frequency Range 1. Main Waveforms: 100µHz-10MHz 2. Built-in Arbitrary: 10mHz-100kHz 3. Arbitrary Waveforms: 10mHz-100kHz
 Resolution 1 µHz
Freq. Accuracy ≤ ±5 PPm
Temperature Coefficient ≤ 2 PPm/°C
Output Characteristic
Amplitude Sine: 1mVpp-10Vpp (50Ω) 2mVpp-20Vpp (Open) Square: 1mVpp-10Vpp (50Ω), 2mVpp-20Vpp (Open)
Accuracy ±1%+0.2mV (Sine 1kHz)
Flatness Amplitudes≤1Vpp (50Ω load): ≤ ±0.5dB Amplitude>1Vpp (50Ω load): ≤±0.5dB (20MHz), ≤±1Db (40MHz or above)
Resolution 4 digit display: 0.1 Mv (Output and Offset)
DC Offset 1Vpp/2+DCI ≤ 5 (50Ω load), 1Vpp/2+DCI ≤ 10 (Open), Accuracy: ±10%+2mV
Units Vpp, mVpp, dBm, Vrms, mVrms
Pulse Duty Rate 0.1%-99.9% (F≤10KHz), 1%-99% (10KHz<F<100KHz)
Modulation
Amplitude Modulation (AM)
Carrier Waveform Sine, Square
Carrier Freq. Range 100µHz-10MHz
Modulation Waveform Sine, Square, Triangle, +Ramp, +Pulse, Rise/fall exponential, Rise/fall logarithm, Gauss noise, Cardiac, SIN(X)/X, DC.
Modulation Freq. Range 100µHz-20kHz
Modulation Depth 1%-120%
Modulation Distortion <2%
Source INT/EXT (Ext. AM: ±5V=100%)
Frequency Modulation (FM)
Carrier Waveform Sine, Square
Carrier Freq. Range 100µHz-10MHz
Modulation Waveform Sine, Square, Triangle, ±Ramp, +Pulse, Rise/fall exponential, Rise/fall logarithm, Gauss noise, Cardiac, SIN(X)/X, DC.
Modulation Freq. Range 100µHz-10kHz
Max. Deviation 50% of carrier freq.
Frequency-shift Keying (FSK)
Waveform Sine, Square
Frequency Range 100µHz-10MHz
Alternate Time 0.1ms-100s ±1% (10mHz-10kHz)
Control Mode INT/EXT (External TTL level, F1: low-level, F2: high-level)
Phase-shift Keying (PSK)
Waveform Sine, Square
Frequency Range 100µHz-10MHz
Phase Range (P1, P2) 0-360°, Resolution: 0.1°
Alternate Time 0.1ms-100s ±1%
Control Mode INT/EXT (External TTL level, P1: low-level, P2: high-level)
Burst
Waveform Sine, Square, Triangle, ±Ramp, ±Pulse, Rise/fall exponential, Rise/fall logarithm, Cardiac, SIN(X)/X.
Frequency Range 10mHz-100KHz
Counting 1-10000 circles
Start Phase 0-360°, Resolution: 0.1°
Alternate Rate 0.1ms-100S  ±1%
Trigger Source INT, EXT, Single
Sweep
Waveform Sine, Square
Frequency Range 100µHz-10MHz
Amplitude Range (F≤40MHz) 1mVpp-10Vpp (50Ω), 2mVpp-20Vpp (Open) (F>40MHz) 1mVpp-1Vpp (50Ω), 2mVpp-2Vpp (Open)
Sweep Mode Linear, Logarithmic, Rise, Fall, Single
Sweep Time 0.1ms-100s  ±1%
Trigger Source INT, Single
Storage Characteristic
Parameters Freq., Amplitude, Waveform, DC Offset and Function Status.
Capacity 8 sets of set-ups
Recall Mode Entire set of parameters is recalled with respective number
Storage Time Over 10 years
Frequency Counter (Option)
Freq. Range 1Hz-100MHz, Totalizing: ≤50MHz
Input Resolution 50mVrms (f: 1Hz-50MHz), 100mVrms (f: 1Hz-100MHz)
Input Impedance R>500kΩ, C<30 PF
Coupling AC
Waveforms Sine, Square
Gate Time 10ms -10s continuously variable
Display Digits 8digits (Gate Time >5s)
Counting Capacity ≤4.29 × 109
Measurement Error Time Base Error + Trigger Error (Trigger Error ≤ 0.3 when S/N > 40dB)
Time Base Type: Mini TXCO Basic Freq.: 10MHz Stability: Better than ±1 x10-6 (22°C±5°C)
Others
Interface (Option) RS-232C or GPIB
Line Power Voltage: 198-242V, Freq.: 47 to 53Hz, Power consumption: <35VA
Ambient 0-40°C
Size & Weight 260 × 395 × 100 (mm) Approx.5kg

Notes
1. 10 MHz DDS function generator should adopt suitable line voltage.
2. To avoid electrical shock, the grounding conductor of power cord should be connected to ground.

Maintenance
1. To maintain good ventilation of arbitrary waveform generator, regular cleaning should be carried out.
2. Use a soft cloth with mild detergent and water when cleaning the machine. Please do not spray cleaner directly onto the instrument.

Related Product
  • 20 MHz DDS Function Generator
  • 20 MHz DDS Function Generator20 MHz DDS function generator is an advanced signal generator that can generate a waveform of almost any shape. It can be used for developing, testing and repairing electronic equipment.1. 20 MHz DDS function generator features high resolution, accuracy and stability. 2. VFD display and rubber keypad allow easy operation of arbitrary waveform generator...